Design of Interrogation Protocols for Radiation Dose Measurements Using Optically-Stimulated Luminescent Dosimeters

认领
导出
Link by DOI
反馈
分享
QQ微信 微博
成果类型:
期刊论文
作者:
Abraham, Sara A.;Kearfott, Kimberlee J.*;Jawad, Ali H.;Boria, Andrew J.;Buth, Tobias J.;...
通讯作者:
Kearfott, Kimberlee J.
作者机构:
[Jacobs, Mitchell L.; Abraham, Sara A.; Jawad, Ali H.; Hien Nguyen; Boria, Andrew J.; Buth, Tobias J.; Smith, Travis; Liu, Kevin; Rucinski, Blake D.; Eng, Sheldon C.; Kearfott, Kimberlee J.; Green, Crystal A.; Dawson, Alexander S.; Frank, Samuel J.; Miklos, Joseph A.] Univ Michigan, Dept Nucl Engn & Radiol Sci, 2355 Bonisteel Blvd, Ann Arbor, MI 48109 USA.
[Rafique, Muhammad] Univ Azad Jammu & Kashmir, Dept Phys, Muzaffarabad 13100, Azad Kashmir, Pakistan.
[Tan, Yanliang] Hengyang Normal Univ, Coll Phys & Elect Engn, Hengyang, Hunan, Peoples R China.
通讯机构:
[Kearfott, Kimberlee J.] U
Univ Michigan, Dept Nucl Engn & Radiol Sci, 2355 Bonisteel Blvd, Ann Arbor, MI 48109 USA.
语种:
英文
关键词:
artifact;calibration;comparative study;device failure analysis;devices;equipment design;evaluation study;illumination;optical instrumentation;practice guideline;radiation dose;reproducibility;semiconductor;sensitivity and specificity;standards;thermoluminescence dosimetry;validation study;Artifacts;Calibration;Equipment Design;Equipment Failure Analysis;Guidelines as Topic;Lighting;Optical Devices;Radiation Dosage;Reproducibility of Results;Semiconductors;Sensitivity and Specificity;Thermoluminescent Dosimetry
期刊:
HEALTH PHYSICS
ISSN:
0017-9078
年:
2017
卷:
112
期:
3
页码:
237-245
基金类别:
Prof. Y. Tan was supported by the National Natural Science Foundation of China (Grants # 11075049, 11375058), the Excellent Talents Program of Hengyang Normal University of China, Cooperative Innovation Center for Digitalization of Cultural Heritage in Ancient Villages and Towns, and the Construct Programof the Key Discipline inHunan Province.MuhammadRafique is grateful to theHigher Education Commission of Pakistan for providing postdoctoral fellowship in the form of Grant 2-6(22)/PDFP/HEC/2013/14.
机构署名:
本校为其他机构
院系归属:
物理与电子工程学院
摘要:
Optically-stimulated luminescent dosimeters are capable of being interrogated multiple times post-irradiation. Each interrogation removes a fraction of the signal stored within the optically-stimulated luminescent dosimeter. This signal loss must be corrected to avoid systematic errors in estimating the average signal of a series of optically-stimulated luminescent dosimeter interrogations and requires a minimum number of consecutive readings to determine an average signal that is within a desired accuracy of the true signal with a desired stat...